Products
  • Products
  • Cas lib
  • Buy offers
  • Encyclopedia
  • Msds lib
  • Synthesis
  • Reach Info
  • Suppliers
Home> Hot Product Listed T   > Thiourea

Thiourea

CAS No.:62-56-6
EINECS(EC#):200-543-5
Molecular Weight:76.12
Molecular Formula:CH4N2S (Products with the same molecular formula)
MOL File:62-56-6.mol
Names and Identifiers
Synonyms

sulourea sulfocarbamide thio arbamid2-Thiourea sulphoureaThiourea Thiurea Thiocarbamide Isothiourea sulfouren THU

Inchi
InChI=1/CH4N2S/c2-1(3)4/h(H4,2,3,4)
Canonical Smiles
C(=S)(N)N
Properties
Appearance
white crystals
Density
1.405
Melting Point
171-175℃
Boiling Point
186.8 °C at 760 mmHg
Refractive Index
1.637 (30 C)
Flash Point
66.8 °C
Water
13.6 g/100 mL (20℃)
Solubilities
13.6 g/100 mL (20 °C)
Color/Form
White crystalline solid
Almost colorless, rhombohedral crystals or needles from ethanol
White lustrous crystals
Stability
Stable. Incompatible with strong acids, strong bases, strong oxidizing agents, metallic salts, proteins, hydrocarbons. May react violently with acrolein.
HS Code
29309070
Storage temp
Store at RT.
Spectral properties
MAX ABSORPTION (H2O PH 7.4): 238 NM (LOG E= 4.1); SADTLER REF NUMBER: 3962, 12062 (IR, PRISM); 8315 (IR, GRATING)
Max absorption (methanol): 241 nm (UV)
IR: 4841 (Coblentz Society Spectral Collection)
UV: 3292 (Sadtler Research Laboratories Spectral Collection)
Raman: 941 (Sadtler Research Laboratories Spectral Collection)
MASS: 52446 (NIST/EPA/MSDC Mass Spectral Database 1990 version)
Safety and Handling
Hazard Codes
Xn:Harmful
Risk Statements
R22;R40;R51/53;R63
Safety Statements
S36/37;S61
HazardClass
6.1
Safety

Hazard Codes:?Xn,?N
Risk Statements: 22-40-51/53-63?
R22:Harmful if swallowed.?
R40:Limited evidence of a carcinogenic effect.?
R51/53:Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.?
R63:Possible risk of harm to the unborn child.
Safety Statements: 36/37-61?
S36/37:Wear suitable protective clothing and gloves.?
S61:Avoid release to the environment. Refer to special instructions / safety data sheets.
RIDADR: UN 2811 6.1/PG 3
WGK Germany: 2
RTECS: YU2800000
HazardClass: 6.1
PackingGroup: III
HS Code: 29309070
Hazardous Substances Data: 62-56-6(Hazardous Substances Data)

PackingGroup
III
Skin, Eye, and Respiratory Irritations
... Skin irritant ...
Cleanup Methods
SLUDGE WAS TREATED WITH 5% AQ SOLN OF THIOUREA, SAND & PORTLAND CEMENT AT PH 12.5. LEACHING TEST OF RESULTING CONCRETE SHOWED THAT DISSOLVED CONCN OF MERCURY, CADMIUM,LEAD, COPPER, & ARSENIC WERE FAR BELOW REGULATION LEVELS.
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms. ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal. ... The plastic bag should be sealed immediately. ... The sealed bag should be labelled properly. ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated. ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
Cover with a weak solution of calcium hypochlorite (up to 15%). Transfer into a large breaker. After 12 hours, neutralize with 6m-hydrochloric acid or 6m ammonium hydroxide, if necessary. ...
Transport
UN 2877/2811
Formulations/Preparations
Thiourea is available in the USA as a lab chemical containing 99% active ingredient. The specifications for a West German commercial product were as follows: 99% minimum active ingredient, 0.15% maximum water, 0.1% maximum ash, 0.4% maximum dicyanodiamide and traces of sulfate ion.
Grades: Technical; reagent
Exposure Standards and Regulations
Substances generally prohibited from direct additiion or use as human food. a) Thiourea is the chemical thiocarbamide, CH4N2S. It is a synthetic chemical, is not found in natural products at levels detectable by the official methodology, and has been proposed as an antimycotic for use in dipping citrus. (b) Food containing any added or detectable level of thiourea is deemed to be adulterated under the act.
Reactivities and Incompatibilities
The solid peroxide produced by action of hydrogen peroxide & nitric acid on thiourea (& possibly a hydrogen peroxidate of thiourea dioxide) decomposed violently on drying in air, with evolution of sulfur dioxide & free sulfur.
REACTS WITH VARIOUS SULFHYDRYL-OXIDIZING AGENTS; COMPLEXES & ADDUCTS WITH ORGANIC CMPD, PROTEIN & CERTAIN HYDROCARBONS.
Acrolein polymerizes with release of heat on contact with thiourea.
Incompatible with acrylaldehyde; hydrogen peroxide; nitric acid.
Other Preventative Measures
In the case of the precursor /to aminothiazole/, thiourea, particular attention should be given to the hazard of skin absorption by the provision of protective clothing and adequate sanitary facilities incl showers.
PRECAUTIONS FOR "CARCINOGENS": Smoking, drinking, eating, storage of food or of food & beverage containers or utensils, & the application of cosmetics should be prohibited in any laboratory. All personnel should remove gloves, if worn, after completion of procedures in which carcinogens have been used. They should ... wash ... hands, preferably using dispensers of liq detergent, & rinse ... thoroughly. Consideration should be given to appropriate methods for cleaning the skin, depending on nature of the contaminant. No standard procedure can be recommended, but the use of organic solvents should be avoided. Safety pipettes should be used for all pipetting. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Operations connected with synth & purification ... should be carried out under well-ventilated hood. Analytical procedures ... should be carried out with care & vapors evolved during ... procedures should be removed. ... Expert advice should be obtained before existing fume cupboards are used ... & when new fume cupboards are installed. It is desirable that there be means for decreasing the rate of air extraction, so that carcinogenic powders can be handled without ... powder being blown around the hood. Glove boxes should be kept under negative air pressure. Air changes should be adequate, so that concn of vapors of volatile carcinogens will not occur. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Vertical laminar-flow biological safety cabinets may be used for containment of in vitro procedures ... provided that the exhaust air flow is sufficient to provide an inward air flow at the face opening of the cabinet, & contaminated air plenums that are under positive pressure are leak-tight. Horizontal laminar-flow hoods or safety cabinets, where filtered air is blown across the working area towards the operator, should never be used. ... Each cabinet or fume cupboard to be used ... should be tested before work is begun (eg, with fume bomb) & label fixed to it, giving date of test & avg air-flow measured. This test should be repeated periodically & after any structural changes. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Principles that apply to chem or biochem lab also apply to microbiological & cell-culture labs. ... Special consideration should be given to route of admin. ... Safest method of admin of volatile carcinogen is by injection of a soln. Admin by topical application, gavage, or intratracheal instillation should be performed under hood. If chem will be exhaled, animals should be kept under hood during this period. Inhalation exposure requires special equipment. ... Unless specifically required, routes of admin other than in the diet should be used. Mixing of carcinogen in diet should be carried out in sealed mixers under fume hood, from which the exhaust is fitted with an efficient particulate filter. Techniques for cleaning mixer & hood should be devised before expt begun. When mixing diets, special protective clothing &, possibly, respirators may be required. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": When ... admin in diet or applied to skin, animals should be kept in cages with solid bottoms & sides & fitted with a filter top. When volatile carcinogens are given, filter tops should not be used. Cages which have been used to house animals that received carcinogens should be decontaminated. Cage-cleaning facilities should be installed in area in which carcinogens are being used, to avoid moving of ... contaminated /cages/. It is difficult to ensure that cages are decontaminated, & monitoring methods are necessary. Situations may exist in which the use of disposable cages should be recommended, depending on type & amt of carcinogen & efficiency with which it can be removed. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": To eliminate risk that ... contamination in lab could build up during conduct of expt, periodic checks should be carried out on lab atmospheres, surfaces, such as walls, floors & benches, & ... interior of fume hoods & airducts. As well as regular monitoring, check must be carried out after cleaning-up of spillage. Sensitive methods are required when testing lab atmospheres for chem such as nitrosamines. Methods ... should ... where possible, be simple & sensitive. ... /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Rooms in which obvious contamination has occurred, such as spillage, should be decontaminated by lab personnel engaged in expt. Design of expt should ... avoid contamination of permanent equipment. ... Procedures should ensure that maintenance workers are not exposed. ... Particular care should be taken to avoid contamination of drains or ventilation ducts. In cleaning labs, procedures should be used which do not produce aerosols or dispersal of dust, ie, wet mop or vacuum cleaner equipped with high-efficiency particulate filter on exhaust, which are avail commercially, should be used. Sweeping, brushing & use of dry dusters or mops should be prohibited. ... Contaminated cleaning materials should not be re-used. ... If gowns or towels are contaminated, they should not be sent to laundry, but ... decontaminated or burnt, to avoid any hazard to laundry personnel. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Doors leading into areas where carcinogens are used ... should be marked distinctively with appropriate labels. Access ... limited to persons involved in expt. ... A prominently displayed notice should give the name of the Scientific Investigator or other person who can advise in an emergency & who can inform others (such as firemen) on the handling of carcinogenic substances. /Chemical Carcinogens/
SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. Quality assurance to ascertain the completeness of the cleaning procedures should be implemented before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at end of shift, but should remain at employee's place of work for cleaning.
Protective Equipment and Clothing
Wear rubber gloves & gas mask.
PRECAUTIONS FOR "CARCINOGENS": ... Dispensers of liq detergent /should be available./ ... In animal laboratory, personnel should remove their outdoor clothes & wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... Clothing should be changed daily but ... discarded immediately if obvious contamination occurs ... /also,/ workers should shower immediately. In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. If gowns are of distinctive color, this is a reminder that they should not be worn outside of lab. /Chemical Carcinogens/
Specification

?Thiourea (CAS NO.62-56-6) is also named as 2-Thiopseudourea ; 2-Thiourea ; AI3-03582 ; CCRIS 588 ; Caswell No. 855 ; EPA Pesticide Chemical Code 080201 ; HSDB 1401 ; Isothiourea ; NSC 5033 ; Pseudothiourea ; Pseudourea, 2-thio- ; RCRA waste number U219 ; Sulourea ; THU ; Thiocarbamide ; Thiocarbonic acid diamide ; Thiomocovina ; Thiomocovina [Czech] ; Thiuronium ; Tsizp 34 ; USAF EK-497 ; Urea, 2-thio- ; Urea, thio- ; beta-Thiopseudourea?.?Thiourea (CAS NO.62-56-6) is white crystals or powder . It is water soluble.?Thiourea is?toxic and carcinogenic. When heated to decomposition?Thiourea emits very toxic fumes of oxides of sulfur and oxides of nitrogen. Violent exothermic polymerization reaction with acrylaldehyde (acrolein), violent decomposition of the reaction product with hydrogen peroxide and nitric acid , spontaneous explosion upon grinding with potassium chlorate. Poisonous inhaled or swallowed. Irritating to skin; may cause allergic skin eruptions.

Octanol/Water Partition Coefficient
log Kow = -1.08
Disposal Methods
Generators of waste (equal to or greater than 100 kg/mo) containing this contaminant, EPA hazardous waste number U219, must conform with USEPA regulations in storage, transportation, treatment and disposal of waste. [
A potential candidate for rotary kiln incineration at a temperature range of 820 to 1,600 deg C and residence times of seconds for liquids and gases, and hours for solids. A potential candidate for fluidized bed incineration at a temperature range of 450 to 980 deg C and residence times of seconds for liquids and gases, and longer for solids.
The following wastewater treatment technology has been investigated for thiourea: Concentration process: Biological treatment.
PRECAUTIONS FOR "CARCINOGENS": There is no universal method of disposal that has been proved satisfactory for all carcinogenic compounds & specific methods of chem destruction ... published have not been tested on all kinds of carcinogen-containing waste. ... Summary of avail methods & recommendations ... /given/ must be treated as guide only. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Total destruction ... by incineration may be only feasible method for disposal of contaminated laboratory waste from biological expt. However, not all incinerators are suitable. ... Most efficient type ... is probably the gas-fired type, in which a first-stage combustion with a less than stoichiometric air:fuel ratio is followed by a second stage with excess air. Some ... are designed to accept ... aqueous & organic-solvent solutions, otherwise it is necessary ... to absorb soln onto suitable combustible material, such as sawdust. Alternatively, chem destruction may be used, esp when small quantities ... are to be destroyed in laboratory. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": HEPA (high-efficiency particulate arrestor) filters ... can be disposed of by incineration. For spent charcoal filters, the adsorbed material can be stripped off at high temp & carcinogenic wastes generated by this treatment conducted to & burned in an incinerator. ... LIQUID WASTE: ... Disposal should be carried out by incineration at temp that ... ensure complete combustion. SOLID WASTE: Carcasses of lab animals, cage litter & misc solid wastes ... should be disposed of by incineration at temp high enough to ensure destruction of chem carcinogens or their metabolites. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Small quantities of ... some carcinogens can be destroyed using chem reactions ... but no general rules can be given. ... As a general technique ... treatment with sodium dichromate in strong sulfuric acid can be used. The time necessary for destruction ... is seldom known ... but 1-2 days is generally considered sufficient when freshly prepd reagent is used. ... Carcinogens that are easily oxidizable can be destroyed with milder oxidative agents, such as sat soln of potassium permanganate in acetone, which appears to be a suitable agent for destruction of hydrazines or of compounds containing isolated carbon-carbon double bonds. Concn or 50% aqueous sodium hypochlorite can also be used as an oxidizing agent. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Carcinogens that are alkylating, arylating or acylating agents per se can be destroyed by reaction with appropriate nucleophiles, such as water, hydroxyl ions, ammonia, thiols & thiosulfate. The reactivity of various alkylating agents varies greatly ... & is also influenced by sol of agent in the reaction medium. To facilitate the complete reaction, it is suggested that the agents be dissolved in ethanol or similar solvents. ... No method should be applied ... until it has been thoroughly tested for its effectiveness & safety on material to be inactivated. For example, in case of destruction of alkylating agents, it is possible to detect residual compounds by reaction with 4(4-nitrobenzyl)-pyridine. /Chemical Carcinogens/
Reach Info
This substance has been officially registered by enterprises.
ECHA (EU chemicals Management Agency) published the completed registration file as follows:
Completed registration file:
Registered as ubmitted Total tonnage band  
FULL JOINT 100_1000 view >
Registered companies:
Registrant / Supplier details Latest dossier received
AlzChem AG 2016
more >
MSDS

Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 12, 2017

Revision Date: Aug 12, 2017

1.Identification

1.1 GHS Product identifier

Product name thiourea

1.2 Other means of identification

Product number -
Other names THU

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

Company XiXisys.com
Address XiXisys.com
Telephone XiXisys.com
Fax XiXisys.com

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Acute toxicity - Oral, Category 4

Carcinogenicity, Category 2

Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 2

Reproductive toxicity, Category 2

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Warning

Hazard statement(s)

H302 Harmful if swallowed

H351 Suspected of causing cancer

H411 Toxic to aquatic life with long lasting effects

Precautionary statement(s)
Prevention

P264 Wash ... thoroughly after handling.

P270 Do not eat, drink or smoke when using this product.

P201 Obtain special instructions before use.

P202 Do not handle until all safety precautions have been read and understood.

P280 Wear protective gloves/protective clothing/eye protection/face protection.

P273 Avoid release to the environment.

Response

P301+P312 IF SWALLOWED: Call a POISON CENTER/doctor/\u2026if you feel unwell.

P330 Rinse mouth.

P308+P313 IF exposed or concerned: Get medical advice/ attention.

P391 Collect spillage.

Storage

P405 Store locked up.

Disposal

P501 Dispose of contents/container to ...

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
thiourea thiourea 62-56-6 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact

Wash off with soap and plenty of water. Consult a physician.

In case of eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

no data available

4.3 Indication of immediate medical attention and special treatment needed, if necessary

no data available

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

5.2 Specific hazards arising from the chemical

no data available

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

6.3 Methods and materials for containment and cleaning up

Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state white crystals
Colour no data available
Odour no data available
Melting point/ freezing point 177\u00b0C(lit.)
Boiling point or initial boiling point and boiling range 97\u00b0C(lit.)
Flammability no data available
Lower and upper explosion limit / flammability limit no data available
Flash point 11\u00b0C(lit.)
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity no data available
Solubility In water:13.6 g/100 mL (20 \u00baC)
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure no data available
Density and/or relative density 1.405
Relative vapour density no data available
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions

no data available

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

no data available

10.6 Hazardous decomposition products

no data available

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN3077 IMDG: UN3077 IATA: UN3077

14.2 UN Proper Shipping Name

ADR/RID: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S.
IMDG: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S.
IATA: ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID, N.O.S.

14.3 Transport hazard class(es)

ADR/RID: 9 IMDG: 9 IATA: 9

14.4 Packing group, if applicable

ADR/RID: III IMDG: III IATA: III

14.5 Environmental hazards

ADR/RID: yes IMDG: yes IATA: yes

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
thiourea thiourea 62-56-6 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 12, 2017
Revision Date Aug 12, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.

Precursor and Product
product :
82118-18-1
82118-18-1
Computational chemical data

Molecular Weight:76.12086 [g/mol]
Molecular Formula:CH4N2S
XLogP3-AA:-0.8
H-Bond Donor:2
H-Bond Acceptor:1
Rotatable Bond Count:0
Tautomer Count:2
Exact Mass:76.009519
MonoIsotopic Mass:76.009519
Topological Polar Surface Area:84.1
Heavy Atom Count:4
Formal Charge:0
Complexity:29
Isotope Atom Count:0
Defined Atom Stereocenter Count:0
Undefined Atom Stereocenter Count:0
Defined Bond Stereocenter Count:0
Undefined Bond Stereocenter Count:0
Covalently-Bonded Unit Count:1
Feature 3D Acceptor Count:1
Feature 3D Donor Count:2
Effective Rotor Count:0
Conformer Sampling RMSD:0.4
CID Conformer Count:1