Home> Hot Product Listed C   > Carbon nanotubes

Carbon nanotubes

CAS No.:1333-86-4
EINECS(EC#):215-609-9
Molecular Weight:12.01
Molecular Formula:C (Products with the same molecular formula)
MOL File:1333-86-4.mol
Properties
Appearance
rod
Density
~1.7 g/mL at 25 °C(lit.)
Melting Point
3550 °C(lit.)
Boiling Point
500-600 °C(lit.)
Vapour
205000mmHg at 25°C
Flash Point
>230 °F
Water
Insoluble
Solubilities
Insoluble in water
Color/Form
Fine black powder
Black solid
Stability
Stable. Combustible.
Storage temp
Keep away from sources of ignition. Store in a cool, dry place. Store in a tightly closed container. Keep from contact with oxidizing materials.
Safety and Handling
Hazard Codes
Xi:刺激性物质‖F;
Risk Statements
R36/37/38
Safety Statements
S26
HazardClass
4.1
Safety

Hazard Codes :?FlammableF,IrritantXi,HarmfulXn
Risk Statements : 36/37-18-11-40
R36/37:? Irritating to eyes and respiratory system?
R18:? In use may form flammable/explosive vapor-air mixture?
R11:? Highly Flammable?
R40:? Limited evidence of a carcinogenic effect
Safety Statements : 26-36-24/25-22
S26:? In case of contact with eyes, rinse immediately with plenty of water and seek medical advice?
S36:? Wear suitable protective clothing?
S24/25:? Avoid contact with skin and eyes?
S22:? Do not breathe dust
RIDADR : UN 1325 4.1/PG 3
WGK Germany : 3?
HazardClass : 4.1
PackingGroup : III
RTECS : FF5250100

PackingGroup
III
Skin, Eye, and Respiratory Irritations
May cause skin and respiratory irritation.
As superficial foreign bodies, carbon black ... may be slightly irritating mechanically and may cause discoloration of lids and conjunctivae, but they are chemically inert.
Cleanup Methods
Electroflotation coagulation separation of carbon black from acetylene production wastewater was studied.
If carbon black is spilled or leaked, the following steps should be taken: Remove all ignition sources. Ventilate area of spill or leak. Carbon black dust may be collected by vacuuming with an appropriate high efficiency filtration system or by using wet methods; it should then be placed in an appropriate container. If a vaccum system is used, there should be no sources of ignition in the vicinity of the spill, and flashback prevention devices should be provided.
/SRP: If time permits, pits, ponds, lagoons, soak holes, or holding areas should be sealed with an impermeable flexible membrane liner./ Land spill - Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents.
Environmental considerations: Water spill Use natural barriers or oil spill control booms to limit spill travel. Remove trapped material with suction hoses.
Environmental Considerations: Air spill Apply water spray or mist to knock down vapors.
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
Transport
UN 1361
Fire Fighting Procedures
If material on fire or involved in fire: Do not extinguish fire unless flow can be stopped Use water in flooding quantities as fog Solid streams of water may spread fire Cool all affected containers with flooding quantities of water Apply water from as far a distance as possible Use foam, dry chemical, or carbon dioxide
Fire Potential
SLIGHT, WHEN EXPOSED TO HEAT OR FLAME.
Carbon black can be ignited in the presence of open flames, and burns slowly with production of carbon monoxide.
Formulations/Preparations
DEPENDING ON THE PROCESS OF MANUFACTURE THERE ARE VARIATIONS IN THE CHEM COMPOSITION OF CARBON BLACK. IT CONTAINS 88-99.5% OF CARBON; 0.3-11% OF OXYGEN; 0.1-1% OF HYDROGEN; UP TO 1% INORG MATERIALS; SMALL AMT OF TARRY MATTER AND TRACES OF SULFUR.
FORMS: POWDER; PELLETS; PASTES. GRADES: (ASTM) /AMERICAN SOCIETY FOR TESTING & MATERIALS/ N660, N550, N330, N110, N220, N761, N762, N601, 5300 (CHANNEL), 5301.
Grades: HAF (high abrasion furnace), FEF (fast extrusion furnace), SRF (semireinforcing furnace), HMF (high modules furnace), GPF (general purpose furnace), SAF (super abrasion furnace), ISAF (intermediate abrasion furnace), FF (fine furnace), XCF (electrically conductive furnace), APF (all-purpose furnace), FT (fine thermal), MT (medium thermal), MT-NS-FF (medium thermal, non-staining, free flowing)
Exposure Standards and Regulations
Carbon black, channel process is an indirect food additive for use only as a component of adhesives.
Reactivities and Incompatibilities
Strong oxidizers such as chlorates, bromates, and nitrates.
Other Preventative Measures
SRP: Local exhaust ventilation should be applied wherever there is an incidence of point source emissions or dispersion of regulated contaminants in the work area. Ventilation control of the contaminant as close to its point of generation is both the most economical and safest method to minimize personnel exposure to airborne contaminants.
SRP: The scientific literature for the use of contact lenses in industry is conflicting. The benefit or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.
... SUBSTITUTION OF LESS IRRITATING SUBSTANCES ... REDESIGN OF OPERATIONS ... PREVENT CONTACT, PROVISION OF A PHYSICAL BARRIER AGAINST CONTACT, PROPER WASHING FACILITIES, WORK CLOTHING AND STORAGE FACILITIES, PROTECTIVE CLOTHING, AND BARRIER CREAMS. MEDICAL CONTROL ...
The employer shall ensure that respirators are adequately maintained, and stored in a dust free condition and that employees are instructed and drilled at least annually in the proper use, fit, and testing for leakage of respirators assigned to them. ... The employer shall ensure that, at the conclusion of the workshift, all clothing is removed only in change rooms. ... And that contaminated protective clothing that is to be cleaned, laundered, or disposed of is placed in a closed container in the change room.
The employer shall ensure that each employee ... /exposed/ to carbon black is informed of the hazards and relevant symptoms of exposure to carbon black. Workers shall be advised that exposure to carbon black may cause transient or permanent lung damage or skin irritation, and that polycyclic aromatic hydrocarbons present in preparation pose a carcinogenic risk.
Eating, preparing, storing, or the dispensing of food (including vending machines) shall be prohibited in all work areas where exposures to carbon black may occur. Smoking shall be prohibited in all the work areas where there is occupational exposure to carbon black. Employees who handle carbon black or who work in an area where they are exposed to carbon black shall be instructed to wash their hands with soap or skin cleaners and water before using toilet facilities, drinking, eating, or smoking and to shower or bathe using soap or other skin cleansers at the end of each workshift before leaving the work premises. The employer shall provide change rooms equipped with shower facilities, and separate storage facilities for street clothes and for protective clothing and equipment. The change rooms shall be in a nonexposure area.
The worker should wash daily at the end of each work shift, and prior to eating, drinking, smoking, etc.
Clothing which is contaminated with carbon black should be removed immediately and placed in closed containers for storage until it can be discarded or until provision is made for the removal of carbon black from the clothing. If the clothing is to be laundered or cleaned, the person performing the operation should be informed of carbon black's hazardous properties. Reusable clothing and equipment should be checked for residual contamination before reuse or storage.
Workers who handle carbon black should wash their faces, hands, and forearms thoroughly with soap and water before eating, smoking, or using toilet facilities.
If material not on fire and not involved in fire: Keep sparks, flames, and other sources of ignition away Keep material out of water sources and sewers Build dikes to contain flow as necessary Attempt to stop leak if without undue personnel hazard Use water spray to knock-down vapors
Avoid breathing vapors. Keep upwind. Wear appropriate chemical protective gloves, boots and goggles. Do not handle broken packages unless wearing appropriate personal protective equipment. Wash away any material which may have contacted the body with copious amounts of water or soap and water.
SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. Quality assurance to ascertain the completeness of the cleaning procedures should be implemented before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at end of shift, but should remain at employee's place of work for cleaning.
SRP: Wastewater from contaminant suppression, cleaning of protective clothing/equipment, or contaminated sites should be contained and evaluated for subject chemical or decomposition product concentrations. Concentrations shall be lower than applicable environmental discharge or disposal criteria. Alternatively, pretreatment and/or discharge to a POTW is acceptable only after review by the governing authority. Due consideration shall be given to remediation worker exposure (inhalation, dermal and ingestion) as well as fate during treatment, transfer and disposal. If it is not practicable to manage the chemical in this fashion, it must meet Hazardous Material Criteria for disposal.
PRECAUTIONS FOR "CARCINOGENS": Smoking, drinking, eating, storage of food or of food & beverage containers or utensils, & the application of cosmetics should be prohibited in any laboratory. All personnel should remove gloves, if worn, after completion of procedures in which carcinogens have been used. They should ... wash ... hands, preferably using dispensers of liq detergent, & rinse ... thoroughly. Consideration should be given to appropriate methods for cleaning the skin, depending on nature of the contaminant. No standard procedure can be recommended, but the use of organic solvents should be avoided. Safety pipettes should be used for all pipetting. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": In animal laboratory, personnel should remove their outdoor clothes & wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... Clothing should be changed daily but ... discarded immediately if obvious contamination occurs ... /also,/ workers should shower immediately. In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. If gowns are of distinctive color, this is a reminder that they should not be worn outside of lab. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Operations connected with synth & purification ... should be carried out under well-ventilated hood. Analytical procedures ... should be carried out with care & vapors evolved during ... procedures should be removed. ... Expert advice should be obtained before existing fume cupboards are used ... & when new fume cupboards are installed. It is desirable that there be means for decreasing the rate of air extraction, so that carcinogenic powders can be handled without ... powder being blown around the hood. Glove boxes should be kept under negative air pressure. Air changes should be adequate, so that concn of vapors of volatile carcinogens will not occur. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Vertical laminar-flow biological safety cabinets may be used for containment of in vitro procedures ... provided that the exhaust air flow is sufficient to provide an inward air flow at the face opening of the cabinet, & contaminated air plenums that are under positive pressure are leak-tight. Horizontal laminar-flow hoods or safety cabinets, where filtered air is blown across the working area towards the operator, should never be used ... Each cabinet or fume cupboard to be used ... should be tested before work is begun (eg, with fume bomb) & label fixed to it, giving date of test & avg air-flow measured. This test should be repeated periodically & after any structural changes. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Principles that apply to chem or biochem lab also apply to microbiological & cell-culture labs ... Special consideration should be given to route of admin. ... Safest method of administering volatile carcinogen is by injection of a soln. Admin by topical application, gavage, or intratracheal instillation should be performed under hood. If chem will be exhaled, animals should be kept under hood during this period. Inhalation exposure requires special equipment. ... Unless specifically required, routes of admin other than in the diet should be used. Mixing of carcinogen in diet should be carried out in sealed mixers under fume hood, from which the exhaust is fitted with an efficient particulate filter. Techniques for cleaning mixer & hood should be devised before expt begun. When mixing diets, special protective clothing &, possibly, respirators may be required. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": When ... admin in diet or applied to skin, animals should be kept in cages with solid bottoms & sides & fitted with a filter top. When volatile carcinogens are given, filter tops should not be used. Cages which have been used to house animals that received carcinogens should be decontaminated. Cage-cleaning facilities should be installed in area in which carcinogens are being used, to avoid moving of ... contaminated /cages/. It is difficult to ensure that cages are decontaminated, & monitoring methods are necessary. Situations may exist in which the use of disposable cages should be recommended, depending on type & amt of carcinogen & efficiency with which it can be removed. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": To eliminate risk that ... contamination in lab could build up during conduct of expt, periodic checks should be carried out on lab atmospheres, surfaces, such as walls, floors & benches, & ... interior of fume hoods & airducts. As well as regular monitoring, check must be carried out after cleaning-up of spillage. Sensitive methods are required when testing lab atmospheres. ... Methods ... should ... where possible, be simple & sensitive. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Rooms in which obvious contamination has occurred, such as spillage, should be decontaminated by lab personnel engaged in expt. Design of expt should ... avoid contamination of permanent equipment. ... Procedures should ensure that maintenance workers are not exposed to carcinogens. ... Particular care should be taken to avoid contamination of drains or ventilation ducts. In cleaning labs, procedures should be used which do not produce aerosols or dispersal of dust, ie, wet mop or vacuum cleaner equipped with high-efficiency particulate filter on exhaust, which are avail commercially, should be used. Sweeping, brushing & use of dry dusters or mops should be prohibited. Grossly contaminated cleaning materials should not be re-used ... If gowns or towels are contaminated, they should not be sent to laundry, but ... decontaminated or burnt, to avoid any hazard to laundry personnel. /Chemical Carcinogens/
Protective Equipment and Clothing
The employer shall provide and shall require employees working with carbon black to wear appropriate full body clothing, with elastic cuffs at the wrists and ankles, gloves, and shoes, which are resistant to penetration by carbon black to minimize skin contact with carbon black. ... Chemical safety glasses shall be provided to employees experiencing eye irritation during exposure.
Wear appropriate eye protection to prevent eye contact.
Respirator Recommendations: Up to 17.5 mg/cu m Assigned Protection Factor (APF) Respirator Recommendation APF = 5 Any quarter-mask respirator.
Respirator Recommendations: Up to 35 mg/cu m Assigned Protection Factor (APF) Respirator Recommendation APF = 10 Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. APF = 10 Any supplied-air respirator.
Respirator Recommendations: Up to 87.5 mg/cu m Assigned Protection Factor (APF) Respirator Recommendation APF = 25 Any supplied-air respirator operated in a continuous-flow mode. APF = 25 Any powered air-purifying respirator with a high-efficiency particulate filter.
Respirator Recommendations: Up to 175 mg/cu m Assigned Protection Factor (APF) Respirator Recommendation APF = 50 Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. APF = 50 Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter. APF = 50 Any self-contained breathing apparatus with a full facepiece. APF = 50 Any supplied-air respirator with a full facepiece.
Respirator Recommendations: Up to 1750 mg/cu m Assigned Protection Factor (APF) Respirator Recommendation APF = 1000 Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode.
Respirator Recommendations: Emergency or planned entry into unknown concentrations or IDLH conditions: Assigned Protection Factor (APF) Respirator Recommendation APF = 10,000 Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode. APF = 10,000 Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus.
Respirator Recommendations: Escape conditions: Assigned Protection Factor (APF) Respirator Recommendation APF = 50 Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter./Any appropriate escape-type, self-contained breathing apparatus In presence of polycyclicaromatic hydrocarbons: NIOSH.
Respirator Recommendations: At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration: Assigned Protection Factor (APF) Respirator Recommendation APF = 10,000 Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode. APF = 10,000 Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus.
Respirator Recommendations: Escape conditions: Assigned Protection Factor (APF) Respirator Recommendation APF = 50 Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter./Any appropriate escape-type, self-contained breathing apparatus.
PRECAUTIONS FOR "CARCINOGENS": ... Dispensers of liq detergent /should be available./ ... Safety pipettes should be used for all pipetting. ... In animal laboratory, personnel should ... wear protective suits (preferably disposable, one-piece & close-fitting at ankles & wrists), gloves, hair covering & overshoes. ... In chemical laboratory, gloves & gowns should always be worn ... however, gloves should not be assumed to provide full protection. Carefully fitted masks or respirators may be necessary when working with particulates or gases, & disposable plastic aprons might provide addnl protection. ... Gowns ... /should be/ of distinctive color, this is a reminder that they are not to be worn outside the laboratory. /Chemical Carcinogens/
Specification

? Carbon black (CAS NO.1333-86-4), its Synonyms are D&C Black No. 2 ; Pigment black 6 ; Pigment black 7 ; Acetylene black ; Animal bone charcoal ; Aroflow ; Arogen ; Arotone ; Arovel ; Arrow ; Atlantic ; Black Kosmos 33 ; Black pearls .

Disposal Methods
SRP: The most favorable course of action is to use an alternative chemical product with less inherent propensity for occupational exposure or environmental contamination. Recycle any unused portion of the material for its approved use or return it to the manufacturer or supplier. Ultimate disposal of the chemical must consider: the material's impact on air quality; potential migration in soil or water; effects on animal, aquatic, and plant life; and conformance with environmental and public health regulations.
PRECAUTIONS FOR "CARCINOGENS": There is no universal method of disposal that has been proved satisfactory for all carcinogenic compounds & specific methods of chem destruction ... published have not been tested on all kinds of carcinogen-containing waste. ... summary of avail methods & recommendations ... /given/ must be treated as guide only. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Incineration may be only feasible method for disposal of contaminated laboratory waste from biological expt. However, not all incinerators are suitable for this purpose. The most efficient type ... is probably the gas-fired type, in which a first-stage combustion with a less than stoichiometric air:fuel ratio is followed by a second stage with excess air. Some ... are designed to accept ... aqueous & organic-solvent solutions, otherwise it is necessary ... to absorb soln onto suitable combustible material, such as sawdust. Alternatively, chem destruction may be used, esp when small quantities ... are to be destroyed in laboratory. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": HEPA (high-efficiency particulate arrestor) filters ... can be disposed of by incineration. For spent charcoal filters, the adsorbed material can be stripped off at high temp & carcinogenic wastes generated by this treatment conducted to & burned in an incinerator. ... LIQUID WASTE: ... Disposal should be carried out by incineration at temp that ... ensure complete combustion. SOLID WASTE: Carcasses of lab animals, cage litter & misc solid wastes ... should be disposed of by incineration at temp high enough to ensure destruction of chem carcinogens or their metabolites. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": ... Small quantities of ... some carcinogens can be destroyed using chem reactions ... but no general rules can be given. ... As a general technique ... treatment with sodium dichromate in strong sulfuric acid can be used. The time necessary for destruction ... is seldom known ... but 1-2 days is generally considered sufficient when freshly prepd reagent is used. ... Carcinogens that are easily oxidizable can be destroyed with milder oxidative agents, such as saturated soln of potassium permanganate in acetone, which appears to be a suitable agent for destruction of hydrazines or of compounds containing isolated carbon-carbon double bonds. Concn or 50% aqueous sodium hypochlorite can also be used as an oxidizing agent. /Chemical Carcinogens/
PRECAUTIONS FOR "CARCINOGENS": Carcinogens that are alkylating, arylating or acylating agents per se can be destroyed by reaction with appropriate nucleophiles, such as water, hydroxyl ions, ammonia, thiols & thiosulfate. The reactivity of various alkylating agents varies greatly ... & is also influenced by sol of agent in the reaction medium. To facilitate the complete reaction, it is suggested that the agents be dissolved in ethanol or similar solvents. ... No method should be applied ... until it has been thoroughly tested for its effectiveness & safety on material to be inactivated. For example, in case of destruction of alkylating agents, it is possible to detect residual compounds by reaction with 4(4-nitrobenzyl)-pyridine. /Chemical Carcinogens/
Reach Info
This substance has been officially registered by enterprises.
ECHA (EU chemicals Management Agency) published the completed registration file as follows:
Completed registration file:
Registered as ubmitted Total tonnage band  
FULL JOINT 1000000_10000000 view >
Registered companies:
Registrant / Supplier details Latest dossier received
"MAKROCHEM" S.A. 2015
A.Schulman GmbH 2013
AGC Chemicals Europe, Ltd 2014
more >
MSDS

Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 12, 2017

Revision Date: Aug 12, 2017

1.Identification

1.1 GHS Product identifier

Product name carbon black

1.2 Other means of identification

Product number -
Other names carbon

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

Company WWW.GuideChem.COM
Address 8F, Block C, No.3 Building, Zijin Plaza, No.701, Gudun Road, Hangzhou, Zhejiang 310030, China
Telephone +86-571-89739798
Fax 86(21)54365166

1.5 Emergency phone number

Emergency phone number +86-571-89739798
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Not classified.

2.2 GHS label elements, including precautionary statements

Pictogram(s) No symbol.
Signal word

No signal word.

Hazard statement(s)

none

Precautionary statement(s)
Prevention

none

Response

none

Storage

none

Disposal

none

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
carbon black carbon black 1333-86-4 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact

Wash off with soap and plenty of water. Consult a physician.

In case of eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

no data available

4.3 Indication of immediate medical attention and special treatment needed, if necessary

no data available

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

5.2 Specific hazards arising from the chemical

no data available

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

6.3 Methods and materials for containment and cleaning up

Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state no data available
Colour no data available
Odour no data available
Melting point/ freezing point no data available
Boiling point or initial boiling point and boiling range 4827\u00b0C
Flammability no data available
Lower and upper explosion limit / flammability limit no data available
Flash point no data available
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity no data available
Solubility no data available
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure no data available
Density and/or relative density 0.075g/cm3
Relative vapour density no data available
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions

no data available

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

no data available

10.6 Hazardous decomposition products

no data available

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: Not dangerous goods. IMDG: Not dangerous goods. IATA: Not dangerous goods.

14.2 UN Proper Shipping Name

ADR/RID: unknown
IMDG: unknown
IATA: unknown

14.3 Transport hazard class(es)

ADR/RID: Not dangerous goods. IMDG: Not dangerous goods. IATA: Not dangerous goods.

14.4 Packing group, if applicable

ADR/RID: Not dangerous goods. IMDG: Not dangerous goods. IATA: Not dangerous goods.

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
carbon black carbon black 1333-86-4 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 12, 2017
Revision Date Aug 12, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.

Computational chemical data

Molecular Weight:16.04246 [g/mol]
Molecular Formula:CH4
XLogP3-AA:0.6
H-Bond Donor:0
H-Bond Acceptor:0
Rotatable Bond Count:0
Exact Mass:16.0313
MonoIsotopic Mass:16.0313
Topological Polar Surface Area:0
Heavy Atom Count:1
Formal Charge:0
Complexity:0
Isotope Atom Count:0
Defined Atom Stereocenter Count:0
Undefined Atom Stereocenter Count:0
Defined Bond Stereocenter Count:0
Undefined Bond Stereocenter Count:0
Covalently-Bonded Unit Count:1
Effective Rotor Count:0
Conformer Sampling RMSD:0.4
CID Conformer Count:1