Guideview >  Articles >  Property  > Gallium triiodide Polarity

Gallium triiodide Polarity

Gallium triiodide (CAS 13450-91-4) is nonpolar. GaI3 is symmetric, so its bond dipoles cancel and μ = 0 D exactly Dipole moment 0 D (exact by symmetry); dielectric constant ≈1.12022 (gas estimate). Covers geometry, comparison data, QC strategy and. Ochoa6 MIN READOctober 8, 2026
Reviewed by: Guidechem Scientific Editorial Board
Standards: IUPAC & PubChem Guidelines  |  Updated: 2026

Is GaI3 (Gallium triiodide) Polar or Nonpolar? Molecular Polarity & Structure Analysis

Gallium triiodide Polarity Cover
GaI3 (Gallium triiodide) is a nonpolar molecule. The molecule is trigonal planar with identical ligands about the Ga centre, so the bond dipoles cancel as vectors; the vector sum of the bond dipoles is therefore zero and the net molecular dipole moment is μ = 0 D. It carries no hydrogen-bond donor, and the Crippen partition coefficient is not quoted here because the parameter set does not cover every element in the molecule.

2D Lewis Structure of Gallium triiodide (GaI3)
Figure 1: 2D Lewis Structure (GaI 3; trigonal planar Ga centre)

Polarity Parameters of GaI3

CAS Registry Number 13450-91-4
Molecular Formula GaI3
Molecular Weight 450.436 g/mol
Valence Electrons 24
Lewis Structure Guide View GaI3 Lewis Structure Guide
Dipole Moment (μ) 0 D (exact by symmetry)
Dielectric Constant (εr) ≈ 1.12022 (calculated dilute-gas estimate, Debye equation, 298 K, 1 atm)
Snyder Polarity Index (P′) Not conventionally assigned
XlogP3-AA Not computed (Crippen parameters do not cover every element here) (computed descriptor)
Note: Snyder P′ is a chromatographic solvent scale developed for conventional liquid solvents; the zero dipole follows from symmetry and is exact, not a measurement with an error bar; the relative permittivity is a dilute-gas estimate obtained from the Debye equation at 298 K and 1 atm, not a liquid dielectric constant; XlogP is a calculated partition descriptor, not a direct measure of solvent polarity.

1. Molecular Polarity Analysis of Gallium triiodide: Geometry & Dipole Vector

To determine whether Gallium triiodide (GaI3) is polar or nonpolar, the decisive question is whether the bond dipoles of the molecule cancel once its three-dimensional shape is taken into account. Gallium triiodide is an inorganic compound. As set out in the GaI3 Lewis Structure Guide, GaI3 has 4 heavy atoms.

The bond polarities follow from electronegativity. In three dimensions, the Ga centre is trigonal planar, with bond angles near 120°. As a result, the bond dipoles cancel and the net molecular dipole moment is exactly μ = 0 D. Treated as a dilute ideal gas at 298 K and 1 atm, the Debye equation converts that dipole into a relative permittivity of about 1.12022 — a number very close to unity, which is exactly what a gas-phase value should look like.

For formulation and process work, the useful consequences are these: the calculated topological polar surface area is 0.0 Ų, 0 hydrogen-bond donors and 0 hydrogen-bond acceptors and the Crippen partition coefficient is not quoted, because the parameter set does not cover every element in the molecule. PubChem’s curated experimental record adds: Gallium triiodide is Colorless or light yellow odorless powder;.

Valence-electron check: Counting valence electrons from the formula: iodine contributes 3 × 7 = 21, giving 21 = 21 valence electrons. The count excludes Ga, for which this check does not assign a main-group valence.

2. Gallium triiodide: Industrial Use, Handling and Specification

Gallium triiodide (CAS 13450-91-4) is an inorganic compound, supplied as an industrial chemical. Its polarity matters for the same reason it matters for any substance of this class: it decides which phases the material will enter, how strongly it adsorbs onto polar surfaces, and how much energy a separation will cost.

The measured physical behaviour recorded for this substance is consistent with that picture. Physical Description: Colorless or light yellow odorless powder;. These are database values and should be read with the conditions (temperature, purity, pressure) that the source states.

Treated as a dilute gas, the calculated relative permittivity is about 1.12022 at 298 K and 1 atm. That figure is close to unity because a gas is mostly empty space: it is a useful consistency check on the dipole, but it is not the number to use when sizing a liquid process, where condensed-phase permittivity and specific interactions dominate.

The structure carries no strongly polar functional group, so the intermolecular forces are dominated by dispersion rather than by dipole–dipole attraction or hydrogen bonding.

PubChem’s GHS record for this substance lists H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation] and H317 (97.8%): May cause an allergic skin reaction [Warning Sensitization, Skin]. Those classifications, not the polarity of the molecule, normally determine packaging, labelling, ventilation and transport requirements.

Industrial Sourcing & Compliance Insight: For Gallium triiodide, the commercially relevant specification is assay, grade, water content and the impurity profile declared on the certificate of analysis, together with the packaging and transport class required for the destination market. Request the certificate of analysis with the enquiry rather than after it: for a substance handled at industrial scale, the declared impurity profile usually decides whether a lot is usable more often than the nominal purity does.

Recommended Analytical Quality-Control Strategy

  • Identity confirmation: FTIR or Raman against a reference spectrum, supported by GC–MS or LC–MS where the compound is amenable; this is the fastest way to catch a mis-labelled lot.
  • Assay / purity: GC-FID or GC-MS for volatile material, HPLC with a validated detector for non-volatile or thermally labile material; state the basis (area %, assay on dried substance, or titrimetric) on the certificate of analysis.
  • Water content: Karl Fischer titration is the default for a substance whose polarity and hydrogen-bonding capacity make it hygroscopic; moisture is the single most common cause of out-of-specification lots.
  • Related substances: a gradient HPLC or GC method capable of resolving the synthesis by-products and the isomeric impurities typical of this structure.
  • Physical constants: density, refractive index and boiling or melting range against the published values — cheap, fast and often sufficient to reject a lot before any chromatographic work is done.

In short, specify Gallium triiodide by assay, water content, impurity profile, packaging and transport class, and state the intended application on the enquiry. The polarity analysis above explains behaviour in use; it does not replace a specification.

3. Polarity Comparison: GaI3 and Related Industrial Fluids

The comparison below places GaI3 next to structurally related substances from the same catalogue. Dipole moments come from one consistent protocol (GFN2-xTB//MMFF94, gas phase, single conformer) and are quoted only where that protocol has been validated; where it has not, the cell says so instead of giving a number. Permittivities are dilute-gas estimates from the Debye equation, logP values are Crippen calculations, and the solubility column is a qualitative inference from the calculated descriptors rather than a measurement.

Compound Dipole Moment Approx. Gas εr log P / XlogP Water Solubility Behavior Industrial Sourcing
GaI3 0 D (symmetry) ≈1.1202 — Colorless or light yellow odorless powder; See supply listing
Cl3I non-zero, not quoted — logP ≈ 2.95 Low to moderate (inferred from logP) See supply listing
BrI3 non-zero, not quoted — logP ≈ 3.50 Low to moderate (inferred from logP) See supply listing
Br3I non-zero, not quoted — logP ≈ 3.42 Low to moderate (inferred from logP) See supply listing
BiI3 non-zero, not quoted — — Not predicted here See supply listing

The spread across this table is the point: composition alone does not set the polarity verdict. GaI3 sits where it does because of the balance between weak dispersion forces and the symmetry of the structure, and any of the neighbouring entries can be the better choice once the temperature, the phase and the required polarity window are fixed.

4. Expert R&D Commentary

Expert Chemical Commentary
“The zero dipole of GaI 3 is not a small number that happens to round to zero — it follows from symmetry, so no improvement in the calculation will move it. No calculated partition coefficient is quoted, because the Crippen parameter set does not cover every element in the molecule. The curated experimental record is consistent: Colorless or light yellow odorless powder;.”

5. Regulatory, Safety & Sustainability Trends

Regulatory status is specific to the substance and to the jurisdiction, and it changes. For CAS 13450-91-4 the authoritative public sources are the ECHA registered-substance database for the EU, and the OSHA and NIOSH tables for occupational exposure in the United States.

PubChem’s GHS record for this substance lists H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation] and H317 (97.8%): May cause an allergic skin reaction [Warning Sensitization, Skin]. These statements are the ones that must appear on the label and in section 2 of the safety data sheet; they, rather than the polarity of the molecule, drive classification, packaging group and transport documentation.

No occupational exposure limit for this substance is quoted in this article, because none was present in the database record used here. Publishing a limit that is not on the record would be worse than publishing none: obtain the applicable value from the OSHA Z-table, the NIOSH pocket guide or the equivalent national instrument before designing the ventilation or monitoring programme.

From a compliance and sustainability standpoint, the polarity of GaI3 is a means rather than an end. It determines which solvent can replace another, how completely the substance can be recovered from a stream, and how much energy the separation will cost — so it belongs in the process justification, while the hazard classification and the exposure limits belong in the safety case.

6. Guidechem's Procurement Tips: What to Specify for Gallium triiodide

A purchase enquiry for Gallium triiodide (CAS 13450-91-4) should state the grade, assay basis, permitted impurity limits, water content, packaging, and the transport and regulatory status required for the destination market. Where the substance is used as a reagent or intermediate, the impurity profile usually matters more than the nominal percentage.

Because polarity governs phase behaviour, it also governs recovery: a exactly zero molecule is easier to strip from a non-polar stream and harder to dry than a non-polar one, and vice versa. Confirm the Guidechem supply listing for current availability and compare lots on the certificate of analysis rather than on the label alone.

Industrial Engineering & Sourcing Specifications

Looking for commercial bulk supplies or technical documentation for Gallium triiodide (CAS 13450-91-4)?

Frequently Asked Questions (FAQs)

Is Gallium triiodide polar or nonpolar?

Gallium triiodide is nonpolar. Its bond dipoles cancel by symmetry, giving μ = 0 D.

Why is the dipole moment of Gallium triiodide zero?

Because the bond dipoles are arranged symmetrically and cancel as vectors. This is an exact symmetry result, not a small measured value, and it does not depend on the accuracy of the calculation.

How does the molecular geometry decide the answer?

The Ga centre is trigonal planar, with bond angles near 120°. The vector sum of the bond dipoles is what remains once the shape is fixed, so geometry — not the mere presence of polar bonds — is the deciding factor.

What is the dielectric constant of Gallium triiodide?

The dilute-gas estimate from the Debye equation at 298 K and 1 atm is about 1.12022. That is a gas-phase number and is close to unity by construction; it is not a liquid dielectric constant, and no liquid value is quoted here unless it appears in the cited database record.

Does Gallium triiodide have a Snyder polarity index?

Not in routine tabulations. Snyder P′ was developed for conventional liquid chromatographic solvents, and this substance is outside the scope of that scale. Dipole moment, calculated logP and hydrogen-bond counts are the descriptors used here instead.

How does Gallium triiodide behave toward water?

The curated database record states: Colorless or light yellow odorless powder;. No calculated partition coefficient is quoted, because the Crippen parameter set does not cover every element in the molecule.

What should be checked before buying Gallium triiodide?

Grade, assay basis, water content, the declared impurity profile, packaging and the transport classification, plus the regulatory status required for the destination market. PubChem’s GHS record for this substance lists H314 (100%): Causes severe skin burns and eye damage [Danger Skin corrosion/irritation] and H317 (97.8%): May cause an allergic skin reaction [Warning Sensitization, Skin].

References & Academic Databases

  1. PubChem Compound Summary: Gallium triiodide, CAS RN 13450-91-4, CID 83478. National Center for Biotechnology Information. pubchem.ncbi.nlm.nih.gov
  2. ECHA Substance Information: Gallium triiodide, CAS 13450-91-4 — REACH registration status, harmonised classification and regulatory context. European Chemicals Agency.
  3. NIST Chemistry WebBook / CCCBDB: experimental geometry, vibrational data and dipole-moment compilations for Gallium triiodide. National Institute of Standards and Technology.
  4. CRC Handbook of Chemistry and Physics, 92nd ed. (Haynes, W. M., ed.), CRC Press, 2011 — electronegativity, dielectric constant and dipole-moment tables.
  5. Nelson, R. D.; Lide, D. R.; Maryott, A. A.: Selected Values of Electric Dipole Moments for Molecules in the Gas Phase, NSRDS-NBS 10, National Bureau of Standards, 1967.
  6. Snyder, L. R.: solvent-polarity classification and the P′ scale for liquid chromatographic solvents. The P′ scale is defined only for conventional liquid solvents and is not assigned to substances outside that scope.
  7. Bannwarth, C.; Ehlert, S.; Grimme, S.: GFN2-xTB — an accurate and broadly parametrised self-consistent tight-binding quantum chemical method with multipole electrostatics and density-dependent dispersion contributions. J. Chem. Theory Comput. 2019, 15 (3), 1652–1671.
  8. RDKit / Halgren, T. A.: MMFF94 force field for geometry generation (J. Comput. Chem. 1996, 17, 490–519) and the RDKit cheminformatics toolkit used for the Crippen logP, TPSA and hydrogen-bond descriptors quoted here.
Technical note: Dipole moment, relative permittivity, Snyder P′ and calculated logP are not interchangeable descriptors. For GaI 3 the zero dipole is a symmetry result and carries no statistical uncertainty. The relative permittivity quoted is a dilute-gas estimate from the Debye equation at 298 K and 1 atm and must not be read as a liquid dielectric constant. Procurement and process decisions should rest on application-specific specifications — grade, assay, water content and impurity profile — supported by measured property data, rather than on a single polarity number.
Make Guideview Preferred Source on Google
Related News
  • Gallium triiodide Polarity
    Gallium triiodide Polarity Gallium triiodide Polarity Gallium triiodide (CAS 13450-91-4) is nonpolar. GaI3 is symmetric, so its bond dipoles cancel and μ = 0 D exactly Dipole moment 0 D (exact by symmetry); dielectric constant ≈1.12022 (gas estimate). Covers geometry, comparison data, QC strategy and.
  • Gallium triiodide Lewis Structure
    Gallium triiodide Lewis Structure Gallium triiodide Lewis Structure Gallium triiodide Lewis structure (GaI3). Ga–I single bond, Ga–I single bond and Ga–I single bond. It shows a trigonal planar shape, sp2 hybridization on Ga, 120° bond angles. Includes a comparison table and FAQs.